Fluorescent lamps
|
Fluorescent lamps are low pressure gas discharge lamps in which the invisible UV radiation generated by the discharge is converted into visible radiation (i.e. light) with the aid of phosphors. (Principle of fluorescence)
Another advantage of ECG operation is the additional energy savings of around 25% for the same luminous flux, comprising:
|
Dimming Dimmable ECGs make use of the property of a choke whereby its inductance increases as the frequency increases. As the operating frequency is made to increase, the choke connected in series with the lamp supplies a progressively lower current. The frequency is controlled via a 1-10 V or a DALI interface. The dimmable ECGs must also ensure that in the dimmed state the cathodes are constantly heated so that they continue to emit electrons even when the lamp current is at a low level.
|
|
Lamp life and resistance to switching transients If fluorescent lamps are operated with CCGs and conventional starters their life is shortened considerably as the frequency of on/off switching increases. The same phenomenon can be observed with cold-start ECGs, which have the ability of starting fluorescent lamps instantly. However, the rapid transition from glow discharge temperature to emission temperature seriously damages the cathodes, so frequent switching cycles reduce the life of fluorescent lamps. Warm start control gear behave in a completely different way. In this case, the cathodes are heated before ignition, which virtually eliminates switching damage to the cathodes. The associated delay in ignition, of around a second is not a serious inconvenience. |
|
Thermal behaviour The physical properties of fluorescent lamps depend on their ambient temperature. This in turn depends on the characteristic temperature sensitivity of the mercury vapour pressure in the lamp. At low temperatures it is too low so there are too few atoms that can be excited. At excessively high temperatures the high vapour pressure results increasingly in self-absorption of the generated UV radiation. The lamps achieve their maximum luminous output at an ambient temperature of approx. 25°C. In the case of T5 lamps with a tube diameter of 16mm (FH, FQ) the rated luminous flux is specified at 25°C, as with other fluorescent lamps but their maximum luminous flux is achieved at an ambient temperature of 33°C to 37°C. In other words, one advantage of T5 lamps is the higher light output from ‘hot’ compact luminaires.
|
![]() Luminous flux of fluorescent lamps as a function of ambient temperature - comparison between T8 and T5 lamps |